CONDEFLEX YSLCY -JZ / -JB /-OZ / OB 300/500V

INSTRUMENTATION AND CONTROL  |  PVC

CONDEFLEX YSLCY -JZ / -JB /-OZ / OB 300/500V

Construction

Conductor: Flexible stranded copper wire. Class 5 acc/. UNE-EN 60228.
Insulation: EN 50363-3 - TI-1 PVC compound.
Identification: JZ: Black Numbered + Yellow/Green, OZ: Black numbered, JB: Color code + Yellow/Green, OB: Color code
Assembly: Concentrically assembled insulated conductors.
Protector: Polyeste tape.
Braid Shielding: Tinned copper (Cu Sn) braid shielding.
Shielding coverage: 80%
Outer sheath: EN 50363-4-1 - PVC compound type TM-2 for outer sheaths
Color: Grey RAL-7001

CONDEFLEX YSLCY -JZ / -JB /-OZ / OB 300/500V
CE CE
Flame retardant Flame retardant
Low halogen Low halogen
Flexible cable Flexible cable
RoHS RoHS

Technical data / Regulations

CPR classification: Eca
Operating voltage: 300/500V
Test voltage: 2.000V 5min
Operating temperature: -15... +70ºC
Standards:
(Construction) Based on DIN VDE 0245 - Cables for electrical and electronic equipment in electrical installations. PVC insulation and outer sheath
(Construction) UNE-EN 50525-2-51 - Low voltage electric cables.Cables for rated voltage less than or equal to 450/750V. General purpose cables. Oil-resistant control cables with thermoplastic insulation (PVC).
(Insulation) EN 50363-3 - TI-1 PVC compound.
(Sheath) EN 50363-4-1 - PVC compound type TM-2 for outer sheaths
(Fire) UNE-EN 60332-1 (IEC 60332-1) - Flame-retardant.
(Fire) UNE-EN 50575 - CPR

Applications

Flexible shielded cable intended for control, signaling, and measurement circuits in machine tools, production machinery, etc., for fixed installations or those with limited mobility, in dry or damp locations where electromagnetic protection is required.