CONDEFLEX SZ1-K (AS+) 0,6/1kV

ENERGY - LOW VOLTAGE  |  FIRE-RESISTANT

CONDEFLEX SZ1-K (AS+) 0,6/1kV

Construction

Conductor: Flexible stranded copper wire. Class 5 acc/. UNE-EN 60228.
Insulation: EN 50363-1 - Silicone cross-linked rubber (SiR) type EI-2.
Identification: HD 308 S2
Assembly: Concentrically assembled insulated conductors.
Outer cover: UNE-EN 21123-4 - Halogen-free polyolefin (type DMZ-E).
Color: Orange

CONDEFLEX SZ1-K (AS+) 0,6/1kV
RoHS RoHS
CPR Compilant CPR Compilant
Halogen free Halogen free
Flexible cable Flexible cable
Fire resistant Fire resistant
Fire retardant Fire retardant
Flame retardant Flame retardant
CE CE

Technical data / Regulations

CPR classification: Cca-s1b, d1, a1
Operating voltage: 0,6/1KV
Test voltage: 3.500 V C.A. 5 min.
Operating temperature: -15...+90ºC (250ºC / 5 segundos en cortocircuito)
Standards:
(Insulation) EN 50363-1 - Cables with intrinsic resistance to fire for use in safety circuits.
(Insulation) EN 50363-1 - Silicone cross-linked rubber (SiR) type EI-2.
(Sheath) UNE-EN 21123-4 - Power cables for industrial use 0,6/1kV. Cross-linked polyethylene insulation (XLPE) and polyolefin sheath. / UNE-EN 21123-4 - Halogen-free polyolefin (type DMZ-E).
(Fire) UNE-EN 50575 - CPR
(Fire) UNE-EN 60754-2 (IEC 60754-2) - Low corrosivity of smoke.
(Fire) UNE-EN 61034 (IEC 61034) - Low smoke emission.
(Fire) UNE-EN 60332-1 (IEC 60332-1) - Flame-retardant.
(Fire) UNE-EN 60332-3 (IEC 60332-3) Cat C - Fire retardant.
(Fire) UNE-EN 60754-1 (IEC 60754-1) - Halogen-free.
(Fire) EN 50200, IEC 60331-2 (for Ø < 20mm) - Intrinsic resistance: PH120 (120 minutes at 840°C).
(Fire) EN 50362, IEC 60331-1 (for Ø > 20mm) - Intrinsic resistance: PH120 (120 minutes at 840 °C).

Observations

Its installation is regulated by the following legislation:

ITC-BT 28 Public premises according to REBT 2002
Annex I of the Fire Safety Regulations in Industrial Establishments.
Basic Fire Safety Document (SI), of the Technical Construction Code.

Applications

Flexible cable for the transport and distribution of electrical energy in fixed installations, protected or not. Cables with intrinsic fire resistance to maintain service of security circuits during a fire, for example: signaling, detection and alarm circuits, circuits for evacuation and fire fighting services, etc. Especially designed for installations in public places where a safe reaction of the cable is required in case of fire, with low smoke opacity and minimizing the harmful effects of corrosive gas inhalation.
Suitable for indoor and outdoor installations (requiring UV protection), on outdoor supports, in tubes or direct burial.